XMD0603 Series

XMD0603 Series

Rated Voltage:9V~15VDC
Hold Current:0.05A~0.20A
Max. Current:40A
Temperature Range:-40℃ to 85℃

Features

o Broadest range of surface mount devices available in the industry

o Faster time to trip than standard surface mount devices

o Available in lead-free version
分享:
Part Number Hold Current Trip Current Rated Voltage Max. Current Typ. Power Max Time to Trip Resistance
IH,A IT,A VMax,VDC IMax,A Pd, W Current Time RMIN R1MAX
XMD0603-0010.010.0360400.50.201.0015.00100.00
XMD0603-0020.020.0660400.50.201.0012.0070.00
XMD0603-0030.030.0930400.50.201.006.0050.00
XMD0603-0040.040.1224400.50.201.004.0040.00
XMD0603-0050.050.1515400.50.500.103.8030.00
XMD0603-0100.100.2515400.50.700.100.908.00
XMD0603-0120.120.309400.50.800.101.105.80
XMD0603-0160.160.409400.51.000.101.004.20
XMD0603-0200.200.459400.52.000.100.553.50

IH=Hold current-maximum current at which the device will not trip at 23 still air.

IT=Trip current-minimum current at which the device will always trip at 23 still air.

trip=Maximum time to trip(s) at assigned current.

IMAX= Maximum fault current device can withstand without damage at rated voltage (V MAX).

VMAX=Maximum voltage device can withstand without damage at its rated current.

PD Typ=Typical power dissipated from device when in tripped state in 23 still air environment.

RMIN=Minimum device resistance at 23.

R1MAX=Maximum device resistance at 23, 1 hour after tripping.

Part Number A B C D E
Min Max Min Max Min Max Min Max Min Max
XMD0603-001 1.401.800.451.000.350.850.100.500.080.40
XMD0603-002 1.401.800.451.000.350.850.100.500.080.40
XMD0603-003 1.401.800.451.000.350.750.100.500.080.40
XMD0603-004 1.401.800.451.000.350.750.100.500.080.40
XMD0603-005 1.401.800.451.000.350.750.100.500.080.40
XMD0603-010 1.401.800.451.000.350.750.100.500.080.40
XMD0603-012 1.401.800.451.000.350.750.100.500.080.40
XMD0603-016 1.401.800.451.000.350.750.100.500.080.40
XMD0603-020 1.401.800.451.000.350.750.100.500.080.40

Temperature -40℃ -20℃ 0℃ 23℃ 30℃ 40℃ 50℃ 60℃ 70℃ 85℃
Derating %157%137%118%100%89%80%70%60%51%37%

IH=Hold current-maximum current at which the device will not trip at 23 still air.

IT=Trip current-minimum current at which the device will always trip at 23 still air.

trip=Maximum time to trip(s) at assigned current.

IMAX= Maximum fault current device can withstand without damage at rated voltage (V MAX).

VMAX=Maximum voltage device can withstand without damage at its rated current.

PD Typ=Typical power dissipated from device when in tripped state in 23 still air environment.

RMIN=Minimum device resistance at 23.

R1MAX=Maximum device resistance at 23, 1 hour after tripping .